[email protected]

Armorcore Level 3 Bullet Resistant Fiberglass Wall Panel

Underwriters Laboratories, Inc., the worlds oldest and largest, not for profit, independent testing company, wrote the standard for bullet resistant materials. The UL752 standard has been widely accepted throughout the world as the standard for architectural bullet resistive building materials. Ballistic Rating Charts for UL752 and NIJRatings of Bullet Resistant materials as identified by:UL 752; Rating Ammunition Weight (grains) Weight (grams) min fps max fps Number of shots; Level 1:9mm Full Metal Copper Jacket with Lead Core:124:8.0:1175:1293:3:Level 2.357 Magnum Jacketed Lead Soft Point:158:10.2:1250:1375:3:Level 3.44 Magnum Lead Semi-Wadcutter Gas Checked

Bullet Resistant & Bulletproof SecureGlass Fast

LEVELS AVAILABLE UL LEVEL 1 TO UL LEVEL 10 * All levels tested by 3rd party ballistic laboratory to the UL 752 Standards, all No Spall* **Low Spall versions tested to the UL 752 Ballistics only, but will not satisfy the UL 752 No Spall Requirement** CFR's Design Ballistic Standards Close Focus Research CFR Small Arms Ballistic Testing and Research Services. We test to UL 752, German DIN, ASTM, Australian, British, Brunswick, Canadian, FRA, MIL-SAMIT, NIJ, State Dept., and standards. We also test Transparent Security Glazings and Bullet Proof Windows. Close Focus Research (CFR) Ballistic Standards Close Underwriters Laboratory UL 752 Level 8 standard: 7.62 NATO; velocity / pattern parameters = 2,750 to 3,025 ft/sec ; 5 shots in a 4.5 inch square Also, the NIJ standard calls for a 0.020 inch type 2024-T3 or T4 Aluminum foil alloy witness plate and the UL 752 standard calls for a 0.125 inch thick corrugated cardboard witness plate to measure the spall characteristics.

Close Focus Research Page 1 of 2 Ballistic Test Report

Underwriters Laboratory UL752 UL Level 10 (.50 cal FMJ Military Ball) 2,810 to 3,091 ft/s 1 shot Intermat Inc. 2045 Placentia Ave., Costa Mesa, California 92627 Phone:866-469-7432 October 5, 2012 Carleton Elliott [email protected] Australian ASTM British Brunswick Canadian Germ DIN FRA MIL-SAMIT NIJ State Dept EN 1063 UL 752 Other CFR Pass Close Focus ResearchPage 1 of 2Ballistic Test ReportJan 04, 2016 · Underwriters Laboratory UL752 UL Level 3 Part 1 (.44 Magnum SWC) 1,350 to 1,485 ft/s [email protected] 3 shots 15.5 inch Intermat Inc. 2045 Placentia Ave., Costa Mesa, California 92627 Phone:866-469-7432 October 2, 2009 13.5 x 15.5 inch 4.0 inch triangle Sample 3 Series 200B Wall Assembly Series 200B Wall Assemblies Australian ASTM British Brunswick Summary of all Ballistic Standards Close Focus Research 187 rows · Underwriters Laboratory UL 752 Ballistic Standards:UL Level 1 Part 1:9 mm Parabellum

UL 752 Level 3 - Super Power Hand Guns Bullet Resistant

UL 752 Level 3 Specifications. Most commonly used protection against hand guns of super power, such as the .44 Magnum, and the like, with muzzle energy of 971-1175 foot-pounds (1317-1593J). UL752 Standard for Bullet Resisting Equipment - Level 3 Paragraph 4.5. UL 752:Standard for Bullet-Resisting EquipmentUL 752:Standard for Bullet-Resisting Equipment. Certification Required:Manufacturers may find it beneficial to obtain an Intertek certification (ETL Mark) to provide third-party assurance of their material's performance characteristics. Scope:Per UL 752, this test method is conducted to determine whether "protection is provided against complete penetration, passage of fragments of UL-752 Certified with Levels 3,4,7,8 & 10 Ballistics UL-752 Certified with Levels 3,4,7,8 & 10 Ballistics Protection. To keep ballistic attacks from penetrating the barriers and reaching or damaging the critical assets, Ideal Utility Services ballistic barriers have been tested by H.P. White Laboratory, Inc. and are certified UL 752:Level 3,4,7, 8 and 10. The UL 752 level is the standard for bullet resisting equipment and means that the equipment is protected from complete

Which Ballistic Standard to Choose - Close Focus Research

May 22, 2017 · Underwriters Laboratory UL 752 Level 8; European Standard EN1063 Level BR6 First of all, the EN1063 has two modes for passing. The EN1063 (NS) "No Splinters" and the EN1063 (S) "Splinters" where glass spall is acceptable. More information about the EN1063 for glazings can be found here:Testing Glazings to the European EN 1063 Ballistic Standards.What is Required for UL752 Ballistic Testing? Close Jan 27, 2011 · For more information about the requirements of the UL 752 standards, see the following page:Underwriters Laboratory UL 752 Ballistic Standards. Example of Test Samples The following images are UL 752 Door Assembly samples. If you submit a Door Assembly, then the frame system must also be tested as shown below.